Shopping Cart

Your cart is empty.

Servo Drive

In Stock
Product Code 8BVI0028HWSS.000-1
Category Servo Drive
Dynamic node allocation (DNA) Yes
Cooling and mounting type Wall mounting
CE YES
UKCA YES
UL cULus E225616 Power conversion equipment
KC YES
product description Nominal 750 VDC Continuous power consumption 2.87 kW Power dissipation depending on switching frequency Switching frequency 5 kHz [0.6 * IM² + 1.3 * IM + 60] W Switching frequency 10 kHz [0.97 * IM² + 0.5 * IM + 110] W Switching frequency 20 kHz [1.7 * IM² - 0.7 * IM + 225] W DC bus capacitance 165 µF Variant ACOPOSmulti backplane 24 VDC power supply Input voltage 25 VDC ±1.6% Input capacitance 23.5 µF Max. power consumption 18 W + PSMC1 + PSLOT2 + P24 V Out + PHoldingBrake Variant ACOPOSmulti backplane 24 VDC output Quantity 2 Output voltage DC bus voltage (UDC): 260 to 315 VDC 25 VDC * (UDC/315) DC bus voltage (UDC): 315 to 800 VDC 24 VDC ±6% Fuse protection 250 mA (slow-blow) electronic, automatic reset Motor connection Quantity 1 Continuous power per motor connection 2.8 kW Continuous current per motor connection 3.8 Aeff Reduction of continuous current depending on switching frequency Switching frequency 5 kHz No reduction Switching frequency 10 kHz No reduction Switching frequency 20 kHz 0.12 A/K (starting at 33°C) Reduction of continuous current depending on installation elevation Starting at 500 m above sea level 0.38 Aeff per 1000 m Peak current 9.5 Aeff Nominal switching frequency 5 kHz Possible switching frequencies 5 / 10 / 20 kHz Insulation stress of the connected motor per IEC TS 60034-25:2004 Limit value curve A Protective measures Overload protection Yes Short-circuit and ground fault protection Yes Max. output frequency 598 Hz Variant U, V, W, PE Connector Shield connection Yes Terminal connection cross section Flexible and fine-stranded wires With wire end sleeve 0.25 to 4 mm² Approbation data UL/C-UL-US 30 to 10 CSA 28 to 10 Terminal cable cross section dimension of shield connection 12 to 22 mm Max. motor line length depending on switching frequency Switching frequency 5 kHz 25 m Switching frequency 10 kHz 25 m Switching frequency 20 kHz 10 m Motor holding brake connection Quantity 1 Output voltage 24 VDC +5.8% / -0% Continuous current per connection 1.1 A Max. internal resistance 0.5 Ω Extinction potential Approx. 30 V Max. extinction energy per switching operation 1.5 Ws Max. switching frequency 0.5 Hz Protective measures Overload and short-circuit protection Yes Open-circuit monitoring Yes Undervoltage monitoring Yes Response threshold for open-circuit monitoring Approx. 0.25 A Response threshold for undervoltage monitoring 24 VDC -2% / -4% Encoder interfaces Quantity 1 Type EnDat 2.2 Connections 9-pin female DSUB connector Status indicators UP/DN LEDs Electrical isolation Encoder - ACOPOSmulti No Encoder monitoring Yes Max. encoder cable length 100 m Depends on the cross section of the power supply wires in the encoder cable Encoder power supply Output voltage Typ. 12.5 V Load capacity 350 mA Protective measures Short-circuit proof Yes Overload-proof Yes Synchronous serial interface Signal transmission RS485 Data transfer rate 6.25 Mbit/s Max. power consumption per encoder interface PSMC[W] = 19 V * IEncoder[A] Trigger inputs Quantity 2 Circuit Sink Electrical isolation Input - Inverter module Yes Input - Input Yes Input voltage Nominal 24 VDC Maximum 30 VDC Switching threshold Low <5 V High >15 V Input current at nominal voltage Approx. 10 mA Switching delay Rising edge 52 µs ±0.5 µs (digitally filtered) Falling edge 53 µs ±0.5 µs (digitally filtered) Modulation compared to ground potential Max. ±38 V Temperature sensor connection Quantity 1 Resistance range 500 Ω to 5 kΩ Electrical properties Discharge capacitance 0.14 µF Energy efficiency (IE classification) Power dissipation relative to continuous apparent power IE2 (10,25) 3.4% IE2 (50,25) 3.4% IE2 (10,50) 3.6% IE2 (50,50) 3.6% IE2 (90,50) 3.6% IE2 (10,100) 4.1% IE2 (50,100) 4.1% IE2 (90,100) 4.1% Nominal losses in standby mode 8.3 W Operating conditions Permissible mounting orientations Hanging vertically Yes Horizontal, face up Yes Standing horizontally No Installation elevation above sea level Nominal 0 to 500 m Maximum 4000 m Pollution degree per EN 61800-5-1 2 (non-conductive pollution) Overvoltage category per EN 61800-5-1 III Degree of protection per EN 60529 IP20 Ambient conditions Temperature Operation Nominal 5 to 40°C Maximum 55°C Storage -25 to 55°C Transport -25 to 70°C Relative humidity Operation 5 to 85% Storage 5 to 95% Transport Max. 95% at 40°C Mechanical properties Dimensions Width 53 mm Height 317 mm Depth Wall mounting 263 mm Weight Approx. 2.6 kg Module width 1
Product Condition New in Box
Available for Immediate Shipment ✔️
Covered by Store Warranty 🟢